TRANSMISSION PROPERTIES AND ELECTRICAL SPECIFICATIONS
FREQ. Insertion Loss NEXT FEXT RL
MHz dB dB dB dB
  Max Min Min Min
1.00 0.02 85.0 84.0 53.0
4.00 0.02 81 75.0 54.0
8.00 0.02 78.0 70.0 56.0
10.00 0.03 77.0 68.0 57.0
16.00 0.03 73.0 58.0 58.0
25.00 0.04 70.0 60.1 60.0
31.25 0.04 68.0 59 57.0
62.50 0.05 64.0 53.0 44.0
100.00 0.06 60.0 49.0 34.0
200.00 0.06 55.0 43.0 23.0
250.00 0.08 52.0 41.0 20.0

Propagation Delay 2.5 nS max @ 1-250 MHz
Propagation Delay Skew 1.25 nS Max.@ 1-250 MHz
Current rating 1.5 A Maks.
Contact resistance 20 mOhm Max  (per contact)
Input/Output resistance  200 mOhm Max.
Input/Output resistance unbalance 50 mOhm Max
Voltage rating 72 Vdc Max
Dielectric strength 1000 Volts rms for 1 minute
Insulation Resistance 100 MegaOhm min @ 500 Vdc
DC Resistance 0.1 Ohm Max. @ 20C
Initial contact resistance 2.5 mOhm
TCL 28-20·Log(f/100) dB min @ 1-250 MHz
Transfer Impedance N/A


ORDERING INFORMATION
HCS P/N Description Blocks Units Size: Hx/Wx/D T568
mm Inch
P6E-02409-1U 24 port RJ-45 Unshielded CAT 6E 19" Phy-FiXX™ Patch Panel 110 IDC 1u 44.5x483 x92 1.75x19x4.25  A