Category 5e Shielded RJ-45 Copper Patch Panels DataLink 100e

TRANSMISSION PROPERTIES AND ELECTRICAL SPECIFICATIONS
Frequency Insertion Loss   NEXT Loss   FEXT Loss   RL
MHz dB   dB   dB   dB
   Nom Max Nom Min Nom Min Nom Min
1.00 0.02 0.10 85.0 65.0 77.0 65.0 55.0 30.0
4.00 0.03 0.10 75.0 65.0 65.0 63.1 50.0 30.0
8.00 0.04 0.11 70.0 64.9 60.0 57.0 48.0 30.0
10.00 0.04 0.13 68.0 63.0 58.0 55.1 42.0 30.0
16.00 0.05 0.16 64.0 58.9 54.0 51.0 40.0 30.0
25.00 0.06 0.20 60.0 55.0 50.0 47.1 35.0 30.0
31.25 0.07 0.22 58.0 53.1 48.0 45.2 33.0 30.0
62.50 0.11 0.32 52.0 47.1 42.0 39.1 28.1 24.1
100.00 0.15 0.40 45.0 43.0 38.0 35.1 24.0 20.0


Propagation Delay 2.5 nS max @ 1-100 MHz
Propagation Delay Skew  1.25 nS max @ 1-100 MHz
Current rating 1.5 A max.
Contact resistance  20 mOhm max (per contact)
Input/Output resistance  200 mOhm max
Input/Output resistance Unbalance 50 mOhm max
Voltage rating 72 Vdc max.
Dielectric strength 1000 Volts rms for 1 minute
Insulation Resistance 500 MegaOhm min @ 500 Vdc
DC Resistance 0.2 Ohm max @ 20C
TCL 28-20·Log(f/100) dB min @ 1-100 MHz
Transfer Impedance 0.1 Ohm @ 1 MHz, 0.2 Ohm @ 10 MHz, 1.6 Ohm @ 80 MHz max.


ORDERING INFORMATION
HCS P/N Description Blocks Units Size T568
mm Inch
P5E-02407-1U 24 port RJ-45 Shielded CAT5e 19’’  110 IDC 1u 44.5x483 1.75x19  B
P5E-02408-1U 24 port RJ-45 Shielded CAT5e 19’’  110 IDC 1u 44.5x483 1.75x19  A
P5E-02409-1U 24 port RJ-45 Shielded CAT5e 19’’  110 IDC 1u 44.5x483 1.75x19 UNI
P5E-02410-1U 24 port RJ-45 Shielded CAT5e 19’’   LSA Plus 1u 44.5x483 1.75x19  B
P5E-02411-1U 24 port RJ-45 Shielded CAT5e 19’’  LSA Plus 1u 44.5x483 1.75x19  A
P5E-02412-1U 24 port RJ-45 Shielded CAT5e 19’’   LSA Plus 1u 44.5x483 1.75x19 UNI