DataLink 250 |
Category 6 U/UTP 100 Ohm Slim Body Modular Cords |
Description |
HCS DataLink 250 modular cord series consists of 100 Ohm impedance, 4-pair U/UTP terminated cords for work area,jumper and patching in local area networks (LANs).HCS DataLink 250 modular cords feature a unique termination method, combining strength relief injection molding into the RJ-45 plug with a removable boot. This design provides the advantages of both molded and non-molded terminations.HCS DataLink 250 modular cords exceed all ANSI/TIA/568-C.2 and ISO/IEC-11801 (2nd Edition) Category 6 requirements and are specially designed to be backward compatible with all Category 6 jacks.The HCS DataLink 250 modular cords can be used with either T568A or T568B modular jacks.The standard color is Gray RAL 7035, but they are available in 10 dierent jacket colors and supplied with boots that match the color of the cord. |
Application | |
HCS DataLink 250 modular cords support all relevant LAN applications, including the following protocols: | |
☑ 1000BASE-T Gigabit Ethernet ☑ ATM 155 ☑ TP-PMD ☑ 100BASE-T "Fast Ethernet" ☑ 100BASE-T2 ☑ 100BASE-T4 ☑ 100BASE-TX ☑ Token Ring 100 Mbps ☑ ATM 52 ☑ ATM 25 ☑ 10BASE-T Ethernet ☑ Token Ring 4 Mbps and 16 Mbps ☑ Broadband and Baseband Video ☑ ISDN Basic and Primary Access ☑ 1BASE-5 Starlan ☑ ISALAN ☑ ITU V.21 and X.11 |
|
Qualifications and Approvals |
|
HCS DataLink 250 Cables are tested and verified for full compliance with the following standards: | |
☑ Category 6 according to
ANSI/TIA-568.2-D ☑ Category 6 according to ISO/IEC-11801 (2nd Edition) |
Benefits & Features |
→ Slim
body design. → Testing every cord prior to shipment - providing the highest degree of quality assurance. → Slim design - fitting in most 24 port 1U panels and wall-outlets. → Exceptional material properties and cable design - providing the highest degree of reliability. → High Return Loss and NEXT Loss values - providing low BER (Bit-Error-Rate) in all applications. → Extremely high pair-balance - providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation and maximizing noise immunity. → Revolutionary pair lay scheme - providing an extremely low delay skew. → Smooth and limp jacket - proving comfortable cord handling. → Unique DoubleSafe™ Quality Assurance Program providing lowest rejection rate available. |
GENERAL PROPERTIES | ||
4 color-coded, unshielded twisted pairs cabled together and overall jacketed. Both cable ends terminated with unshielded modular plug connectors conforming to IEC 60603-7-4. | |
Basic Cable Conductor | Stranded, 24 AWG, 7x0.20 mm, bare annealed copper |
Wire Insulation | Polyolefin |
Number of insulated conductors | 8, twisted in 4 pairs. |
Color Code of Pairs | Blue x White/Blue, Orange x White/Orange, Green x White/Green, Brown x White/Brown. |
Overall Tape Wrap | None. |
Overall shield | None. |
Drain wire | None. |
Outer Jacket and boots | LS0H Halogen free flame retardant or PVC compound. |
Standard Jacket and boot Color | Light Gray RAL 7035. Other colors available upon request. |
Standard Surface Marking | Includes HCS P/N, cable description, Meter mark and Batch Number. |
Cable to plug tensile strength | 9 Kgf (90N) min. |
Pulling force | 1 Kgf (10N) max. |
Storage Temperature | -20 to +80C |
Durability | 750 mating cycles |
Cable OD: | 5.7 mm nom. |
Bend radius | 23 mm min. |
Plug housing material | Polycarbonate, conforming to UL 94 V-0. |
Plug contact material | 50 micro-inches gold plating over 100 micro-inches nickel plated copper alloy. |
Temperature operating range | -20 to +60C |
Flame Test | IEC 60332-1. |
Halogen content in LS0H cables | Null. |