Kategori 7 S/FTP 100 Ohm Yatay LAN Kablolar | DataLink 600 |
İLETİM DEĞERLERİ VE ELEKTRİKSEL ÖZELLİKLER | ||
FREKANS | ZAYIFLAMA | NEXT | PS NEXT | ELFEXT | PS ELFEXT | RL | TCL | EL-TCTL | PS ANEXT | PS AFEXT |
MHz | dB/100m | dB | dB | dB/100m | dB/100m | dB | dB | dB | dB | dB |
Maks | Min | Min | Min | Min | Min | Min | Min | Min | Min | |
1 | NS | 78.0 | 75.0 | 78.0 | 75.0 | 20.0 | 40.0 | 35.0 | 67.0 | 67.0 |
4 | 3.74 | 78.0 | 75.0 | 78.0 | 75.0 | 23.0 | 40.0 | 23.0 | 67.0 | 67.0 |
8 | 5.24 | 78.0 | 75.0 | 75.9 | 72.9 | 24.5 | 40.0 | 16.9 | 67.0 | 67.0 |
10 | 5.86 | 78.0 | 75.0 | 74.0 | 71.0 | 25.0 | 40.0 | 15.0 | 67.0 | 67.0 |
16 | 7.41 | 78.0 | 75.0 | 79.9 | 66.9 | 26.0 | 38.0 | 10.9 | 67.0 | 67.0 |
20 | 8.29 | 78.0 | 75.0 | 68.0 | 65.0 | 25.0 | 37.0 | 9.0 | 67.0 | 67.0 |
25 | 9.29 | 78.0 | 75.0 | 66.0 | 63.0 | 24.3 | 36.0 | 7.0 | 67.0 | 65.2 |
31.25 | 10.41 | 78.0 | 75.0 | 64.1 | 61.1 | 23.6 | 35.1 | 5.1 | 67.0 | 63.3 |
62.5 | 14.88 | 75.5 | 72.5 | 58.0 | 55.1 | 21.5 | 32.0 | NS | 67.0 | 57.3 |
100 | 19.02 | 72.4 | 69.4 | 54.0 | 51.0 | 20.1 | 30.0 | NS | 67.0 | 53.2 |
150 | 23.56 | 69.8 | 66.8 | 50.0 | 47.5 | 18.9 | 28.2 | NS | 67.0 | 49.7 |
200 | 27.47 | 67.9 | 64.9 | 48.0 | 45.0 | 18.0 | 27.0 | NS | 67.0 | 47.2 |
250 | 30.97 | 66.4 | 63.4 | 46.0 | 43.0 | 17.3 | 26.0 | NS | 67.0 | 45.2 |
300 | 34.19 | 65.2 | 62.2 | 44.5 | 41.5 | 17.3 | NS | NS | 67.0 | 43.7 |
400 | 40.01 | 63.4 | 60.4 | 42.0 | 39.0 | 17.3 | NS | NS | 67.0 | 41.2 |
500 | 45.26 | 61.9 | 58.9 | 40.0 | 37.0 | 17.3 | NS | NS | 67.0 | 39.2 |
600 | 50.10 | 60.7 | 57.7 | 38.4 | 35.4 | 17.3 | NS | NS | 65.8 | 37.6 |
Empedans Karakteristiği | 100±5 Ohm @ 1-600 MHz |
DC Direnci | 93.0 Ohm/Km maks. |
Direnç dengesizliği | 2% Maks |
Kapasitans | 45 pF/m nom. @ 1 KHz |
Kapasitans dengesizliği (toprağa göre) | 1500 pF/Km maks. @ 1 KHz |
Voltaj | 72 Vdc Maks |
Dielektrik kuvvet | 700 Volts/1 minute min rms |
Sinyal hızı (NVP) | 77-80% |
Sinyal iletim Süresi (Prop. Delay) | 500+36/f½ @ 1-600 MHz. |
Perler Arası Sinyal Gecikmesi (Skew) | 25 nS/100m Maks @ 1-600 MHz |
İzolasyon direnci | 5000 MegaOhm•Km min. @ 500 Vdc |
Birleşim Zayıflaması | 85 dB min @ 30-100 MHz 85-20Log(f/100) @100-600 MHz |
Ekranlama Zayıflaması | 60 dB min @ 30-600 MHz |
Transfer Empedansı | 10 mOhm/m Maks @ 1-30 MHz 30 MOhm/m Maks @ 30-100 MHz |
SİPARİŞ BİLGİLERİ | ||
HCS P/N | Açıklama | Dış Çap mm |
Ağırlık Kg/Km |
Kal. Değer Kj/m |
Paketleme | Not |
H07-F0401-DP | 4x2x23# S/FTP CAT 7 PVC Gri | 7.0 | 48 | 660 | 500m Makara | - |
H07-F0401-DM | 4x2x23# S/FTP CAT 7 PVC Gri | 7.0 | 48 | 660 | 1000m Makara | - |
H07-F0402-DP | 4x2x23# S/FTP CAT 7 LS0H Gri | 7.0 | 48 | 660 | 500m Makara | - |
H07-F0402-DM | 4x2x23# S/FTP CAT 7 LS0H Gri | 7.0 | 48 | 660 | 1000m Makara | - |
H07-F0803-DP | 2x(4x2x23#) CAT 7 S/FTP PVC Gri | 7.0x14.2 | 100 | 1320 | 500m Makara | FIG-8 |
H07-F0803-DM | 2x(4x2x23#) CAT 7 S/FTP PVC Gri | 7.0x14.2 | 100 | 1320 | 1000m Makara | FIG-8 |
H07-F0804-DP | 2x(4x2x23#) CAT 7 S/FTP LS0H Gri | 7.0x14.2 | 100 | 1320 | 500m Makara | FIG-8 |
H07-F0804-DM | 2x(4x2x23#) CAT 7 S/FTP LS0H Gri | 7.0x14.2 | 100 | 1320 | 1000m Makara | FIG-8 |
Alev Testi Uygunluğu: F=0: IEC 60332-1 F=C: IEC 60332-3-24 F=D: IEC 60332-3-25 |