Kategori 7 F/FTP 100 Ohm Yatay LAN Kablolar | DataLink 600 |
İLETİM DEĞERLERİ VE ELEKTRİKSEL ÖZELLİKLER | ||
FREKANS | Zayıflama | NEXT | PS NEXT | EL FEXT | PS EL FEXT | RL | TCL | EL-TCL | PS ANEXT | PS AFEXT |
MHz | dB/100m | dB | dB | dB/100m | dB/100m | dB | dB | dB | dB | dB |
Maks | Min | Min | Min | Min | Min | Min | Min | Min | Min | |
1 | NS | 78.0 | 75.0 | 78.0 | 75.0 | 20.0 | 40.0 | 35.0 | 67.0 | 67.0 |
4 | 3.74 | 78.0 | 75.0 | 83.3 | 80.3 | 23.0 | 40.0 | 23.0 | 67.0 | 67.0 |
8 | 5.24 | 78.0 | 75.0 | 77.2 | 74.2 | 24.5 | 40.0 | 16.9 | 67.0 | 67.0 |
10 | 5.86 | 78.0 | 75.0 | 75.3 | 72.3 | 25.0 | 40.0 | 15.0 | 67.0 | 67.0 |
16 | 7.41 | 78.0 | 75.0 | 71.2 | 68.2 | 26.0 | 38.0 | 10.9 | 67.0 | 67.0 |
20 | 8.29 | 78.0 | 75.0 | 69.3 | 66.3 | 25.0 | 37.0 | 9.0 | 67.0 | 67.0 |
25 | 9.29 | 78.0 | 75.0 | 67.3 | 64.3 | 24.3 | 36.0 | 7.0 | 67.0 | 65.2 |
31.25 | 10.41 | 78.0 | 75.0 | 65.4 | 62.4 | 23.6 | 35.1 | 5.1 | 67.0 | 63.3 |
62.5 | 14.88 | 75.5 | 72.5 | 59.4 | 56.4 | 21.5 | 32.0 | NS | 67.0 | 57.3 |
100 | 19.02 | 72.4 | 69.4 | 55.3 | 52.3 | 20.1 | 30.0 | NS | 67.0 | 53.2 |
150 | 23.56 | 69.8 | 66.8 | 51.8 | 48.8 | 18.9 | 28.2 | NS | 67.0 | 49.7 |
200 | 27.47 | 67.9 | 64.9 | 49.3 | 46.3 | 18.0 | 27.0 | NS | 67.0 | 47.2 |
250 | 30.97 | 66.4 | 63.4 | 47.3 | 44.3 | 17.3 | 26.0 | NS | 67.0 | 45.2 |
300 | 34.19 | 65.2 | 62.2 | 45.8 | 42.8 | 17.3 | NS | NS | 67.0 | 43.7 |
400 | 40.01 | 63.4 | 60.4 | 43.3 | 40.3 | 17.3 | NS | NS | 67.0 | 41.2 |
500 | 45.26 | 61.9 | 58.9 | 41.3 | 38.3 | 17.3 | NS | NS | 67.0 | 39.2 |
600 | 50.10 | 60.7 | 57.7 | 39.7 | 36.7 | 17.3 | NS | NS | 65.8 | 37.6 |
Empedans Karakteristiği | 100±5 Ohm @ 1-600 MHz |
Direnç Dengesizliği | 2% maks. |
Kapasitans | 45 pF/m nom. @ 1 KHz |
Kapasitans Dengesizligi (toprağa göre) | 1500 pF/Km maks. @ 1 KHz. |
Voltaj | 72 Vdc maks. |
Dielektrik Kuvvet | 700 Volts/1 dakika min rms |
Sinyal Hızı (NVP) | 77-80% |
Sinyal Iletim Süresi (Prop. Delay) | 500+36/f1/2 |
Perler Arası Sinyal Gecikmesi (Skew) | 25 nS/100m maks. @ 1-600 MHz. |
İzolasyon Direnci | 5000 MegaOhm•Km min. @ 500 Vdc |
Bağlantı Zayıflaması | IEC 61156-5 Type 1b |
Ekranlama Zayıflaması | 60 dB min @ 30-600 MHz |
Transfer Empedansı | IEC 61156-5 Grade 1 |
SİPARİŞ BİLGİLERİ | ||
HCS P/N | Açıklama | Dış Çap mm |
Ağırlık Kg/Km |
Kal. Değer Kj/m |
Paketleme | Not |
H07-F0452-DP | 4x2x23# F/FTP CAT 7 LS0H Gri | 7.2 | 53 | 660 | 500m Makara | - |
H07-F0452-DM | 4x2x23# F/FTP CAT 7 LS0H Gri | 7.2 | 53 | 660 | 1000m Makara | - |
H07-F0854-DP | 2x(4x2x23#) CAT 7 F/FTP LS0H Gri | 7.2x14.4 | 106 | 1320 | 500m Makara | FIG-8 |
H07-F0854-DM | 2x(4x2x23#) CAT 7 F/FTP LS0H Gri | 7.2x14.4 | 106 | 1320 | 1000m Makara | FIG-8 |
Alev Testi Uygunluğu: F=0: IEC 60332-1 F=C: IEC 60332-3-24 F=D: IEC 60332-3-25 |